Self-Induced Fault of a Hydraulic Servo Valve A Possible Cause for Hidden Malfunction of Aircraft's Systems /

This report describes recent trouble-shooting results in aircraft engineering concerning a self-induced fault mechanism of a hydraulic servo-valve. It presents a possible root cause for past aircraft accidents and as such helps to avoid such malfunction and its fatal consequences in the future.

Detaylı Bibliyografya
Yazar: Seung, Taehun (Yazar)
Müşterek Yazar: SpringerLink (Online service)
Materyal Türü: e-Kitap
Dil:İngilizce
Baskı/Yayın Bilgisi: Cham : Springer International Publishing : Imprint: Springer, 2019.
Edisyon:1st ed. 2019.
Seri Bilgileri:SpringerBriefs in Applied Sciences and Technology,
Konular:
Online Erişim:Full-text access
OPAC'ta görüntüle
İçindekiler:
  • Introduction
  • Topics and arrangement of this report
  • Occasion for investigation, brief description of the occurrence
  • Appraisal and fundamental contemplation for a pressure controlling servo valve
  • Existence of a self-induced fault of a two stage servo valve - Hypothesis
  • Experimental investigation - Test execution and results
  • Reconstruction of the entire fault working mechanism - interim conclusion
  • Additional reflections / Supplementation of contemplation
  • Conclusion.